Back to Home

Power stability, linewidth, beam quality

PGL-VI-445445 nm violet CW laser

445 nm

PGL-VI-445 is a 445 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. PGL-VI-445/ 1~80mW. Key specifications: output / average power 1~80 mW, operating mode CW, transverse mode Near TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-VI-445

14 specification rows

Wavelength445 nm
Output / average power1~80 mW
Beam / notesPGL-VI-445/ 1~80 mW
Operating modeCW
Transverse modeNear TEM00
Beam diameter at the aperture(1/e2) (mm)~4.5
Beam divergence, full angle (mrad)<1
Expected lifetime (hours)10000
Operating voltage(internal PCB)6VDC
ConnectionCable with flying leads
Operating temperature0°C to 40°C
Storage temperature-20°C to 80°C
Humidity<90%, non-condensing
Dimensions of internal PCB mmΦ12×50
Dimensions of internal PCB1 mmΦ15×90

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

PGL-VI-445: 445 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

PGL-VI-445: 445 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

PGL-VI-445: 445 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Spectrum analysis

PGL-VI-445: 445 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (Near TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect PGL-VI-445 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: 0°C to 40°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam diameter at the aperture(1/e2) (mm): ~4.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of internal PCB mm: Φ12×50 · Dimensions of internal PCB1 mm: Φ15×90
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-VI-445

What cooling does the PGL-VI-445 require?

Operating temperature: 0°C to 40°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-VI-445 deliver?

Transverse mode: Near TEM00 · Beam diameter at the aperture(1/e2) (mm): ~4.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-VI-445 mounted?

Dimensions of internal PCB mm: Φ12×50 · Dimensions of internal PCB1 mm: Φ15×90. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-VI-445 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-VI-445 (current)MDL-445(FC)FC-445
Wavelength445 nm445 nm445 nm
Optical power / pulse energy1~80 mW1~15 W1~30 W
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityNear TEM00<1Confirm for this model