PGL-V-H-730 is a 730 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. OEM Red Laser Module. Key specifications: output / average power 1~1500 mW, operating mode CW, power stability(rms, over 4 hours) <5%, <3%, <1%. View specifications, datasheet and enquiry options from Precisometer.
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
PGL-V-H-730: 730 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
PGL-V-H-730: 730 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
PGL-V-H-730: 730 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Collimation
PGL-V-H-730: Collimation benefits from a stable, focusable source. 730 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Multimode) informs waist size and propagation.
System integration
Integration and compatibility
Use these checks to connect PGL-V-H-730 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Operating temperature: -10°C to 50°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Multimode · Beam divergence, full angle (mrad): <5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of laser head: 92(L)×40(W)×40(H)mm3
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.
Technical FAQ
Integration questions for PGL-V-H-730
What cooling does the PGL-V-H-730 require?+
Operating temperature: -10°C to 50°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the PGL-V-H-730 deliver?+
Transverse mode: Multimode · Beam divergence, full angle (mrad): <5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
How is the PGL-V-H-730 mounted?+
Dimensions of laser head: 92(L)×40(W)×40(H)mm3. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare PGL-V-H-730 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.