Back to Home

Power stability, linewidth, beam quality

PGL-LF-830830 nm near-infrared CW laser

830 nm

PGL-LF-830 is a 830 nm CW laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. OEM Infrared Laser. Key specifications: output / average power 1~10 mW, beam divergence (mrad) <1.5, laser operation mode CW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-LF-830

10 specification rows

Wavelength830 nm
Output / average power1~10 mW
Beam / notesOEM Infrared Laser
Beam divergence (mrad)<1.5
Laser operation modeCW
Modulation optionalTTL 30kHz or analog (0-3V or 0-5V)
ConnectionCable with flying leads
Operating temperature (°C)-10°C to +45°C
Storage temperature (°C)-20°C to +80°C
Humidity (%)< 90 %, non-condensing
Weight (g)45g

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

PGL-LF-830: 830 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

PGL-LF-830: 830 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

PGL-LF-830: 830 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Measurement

PGL-LF-830: Measurement benefits from a stable, focusable source. 830 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.5) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect PGL-LF-830 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): -10°C to +45°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence (mrad): <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Weight (g): 45g
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-LF-830

What cooling does the PGL-LF-830 require?

Operating temperature (°C): -10°C to +45°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-LF-830 deliver?

Beam divergence (mrad): <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-LF-830 mounted?

Weight (g): 45g. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-LF-830 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-LF-830 (current)MDL-830(FC)FC-830
Wavelength830 nm830 nm830 nm
Optical power / pulse energy1~10 mW1~1500 mW1~5 W
Operating mode / pulse widthConfirm for this modelCWConfirm for this model
Beam quality<1.5<1.0Confirm for this model