Back to Home

Power stability, linewidth, beam quality

PGL-FS-445445 nm violet CW laser

445 nm

PGL-FS-445 is a 445 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. PGL-FS-445/ 1~80mW. Key specifications: output / average power 1~80 mW, operating mode CW, power stability(rms, over 4 hours) <5%, <3%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-FS-445

15 specification rows

Wavelength445 nm
Output / average power1~80 mW
Beam / notesPGL-fs-445/ 1~80 mW
Operating modeCW
Power stability(rms, over 4 hours)<5%, <3%, <1%
Transverse modeNear TEM00
Beam diameter at the aperture(1/e2) (mm)~4.5
Beam divergence, full angle (mrad)<1
Warm-up time minutes<10
Expected lifetime (hours)10000
ConnectionCable with flying leads
Operating voltage(PSU-V-OEM)100-240VAC(TTL30kH and Analog 0-5V,optional)
Operating temperature-10°C to 50°C
Storage temperature-20°C to 80°C
Humidity< 90%, non-condensing
Dimensions of laser head77(L)×30(W)×30(H)mm3

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

PGL-FS-445: 445 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

PGL-FS-445: 445 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

PGL-FS-445: 445 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

PGL-FS-445: 445 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (Near TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect PGL-FS-445 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: -10°C to 50°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam diameter at the aperture(1/e2) (mm): ~4.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of laser head: 77(L)×30(W)×30(H)mm3
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-FS-445

What cooling does the PGL-FS-445 require?

Operating temperature: -10°C to 50°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-FS-445 deliver?

Transverse mode: Near TEM00 · Beam diameter at the aperture(1/e2) (mm): ~4.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-FS-445 mounted?

Dimensions of laser head: 77(L)×30(W)×30(H)mm3. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-FS-445 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-FS-445 (current)MDL-445(FC)FC-445
Wavelength445 nm445 nm445 nm
Optical power / pulse energy1~80 mW1~15 W1~30 W
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityNear TEM00<1Confirm for this model