Power stability, linewidth, beam quality

PGL-FP-480480 nm blue CW laser

480 nm

PGL-FP-480 is a 480 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Laser. Key specifications: output / average power 1~20 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-FP-480

2 specification rows

Wavelength480 nm
Output / average power1~20 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~50 mW
  • Output / average power: 1~20 mW
  • Output / average power: 1~30 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours , ±3°C): <5%, <3%

Beam-quality tolerance context

Nearby series records state M²: <2.0, M²: ~3.0, M²: <1.2, and Beam divergence (mrad): <1.5. These are series context, not guaranteed values for PGL-FP-480; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

PGL-FP-480: 480 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

PGL-FP-480: 480 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

PGL-FP-480: 480 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Spectrum analysis

PGL-FP-480: 480 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-FP-480 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-FP-480 (current)MBL-F-480MLL-III-483L
Wavelength480 nm480 nm483 nm
Optical power / pulse energy1~20 mW1~50 mW1~50 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this model<1.5Near TEM00