Back to Home

Power stability, linewidth, beam quality

PGL-FP-13101310 nm infrared CW laser

1310 nm

PGL-FP-1310 is a 1310 nm CW laser. Used for communication, spectrum analysis, measurement, flow cytometry. SM Fiber coupled. Key specifications: output / average power 1~15 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-FP-1310

2 specification rows

Wavelength1310 nm
Output / average power1~15 mW
Beam / notesSM Fiber coupled

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 19 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~2500 mW
  • Output / average power: 1~5 W
  • Output / average power: 1~200 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state M²: <1.1, Beam divergence, full angle (mrad): <3.0, Beam divergence, full angle (mrad): <1.5, and Beam divergence, full angle (mrad): <2.0. These are series context, not guaranteed values for PGL-FP-1310; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser source and internal thermal control
  2. Step 2Configured fiber launch or integrated pigtail
  3. Step 3Mode- and connector-matched patch lead
  4. Step 4Collimator, isolator or experiment input

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Communication

PGL-FP-1310: 1310 nm emission must sit inside the fiber-component passband used for Communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.

Spectrum analysis

PGL-FP-1310: 1310 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

Measurement

PGL-FP-1310: Measurement benefits from a stable, focusable source. 1310 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Flow cytometry

PGL-FP-1310: 1310 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-FP-1310 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-FP-1310 (current)MDL-1310(FC)FC-1310
Wavelength1310 nm1310 nm1310 nm
Optical power / pulse energy1~15 mW1~2500 mW1~5 W
Operating mode / pulse widthConfirm for this modelCWConfirm for this model
Beam qualityConfirm for this modelMultimodeConfirm for this model