OEM-DH-450 is a 450 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Fiber coupling, water cooled. Key specifications: output / average power 15-30 W, operating mode CW, warm-up time (minutes) <5. View specifications, datasheet and enquiry options from Precisometer.

Specifications

OEM-DH-450

13 specification rows

Output / average power15-30 W
Beam / notesFiber coupling, water cooled
Operating modeCW
Warm-up time (minutes)<5
Operating temperature (℃)25+/-3 (OEM-DH-450) / 10-35 (OEM-DH-450-Water)
Power supply (90-264VAC)PSU-H-LED
Expected lifetime (hours)10000
Warranty1 year
Wavelength (nm)450±10
Output power (W)15,16,……30
Power stability (rms, over 4 hours) at 25℃<1%, <3%, <5%
Cooled methodWater Cooled for OEM-DH-450-Water
Modulation optionTTL/Analog 1Hz-5KHz, 1Hz-10KHz, 1Hz-100KHz, and TTL on/off

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

OEM-DH-450: 450 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%, <3%, <5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

OEM-DH-450: 450 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%, <3%, <5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

OEM-DH-450: 450 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%, <3%, <5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

OEM-DH-450: 450 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

System integration

Integration and compatibility

Use these checks to connect OEM-DH-450 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 25+/-3 (OEM-DH-450) / 10-35 (OEM-DH-450-Water) · Cooled method: Water Cooled for OEM-DH-450-Water
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for OEM-DH-450

What cooling does the OEM-DH-450 require?

Operating temperature (℃): 25+/-3 (OEM-DH-450) / 10-35 (OEM-DH-450-Water) · Cooled method: Water Cooled for OEM-DH-450-Water. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare OEM-DH-450 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterOEM-DH-450 (current)MDL-450(FC)FC-450
Wavelength450 nm450 nm450 nm
Optical power / pulse energy15-30 W1~15 W1~30 W
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityConfirm for this model<1Confirm for this model