OEM-DH-450 is a 450 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Fiber coupling, water cooled. Key specifications: output / average power 15-30 W, operating mode CW, warm-up time (minutes) <5. View specifications, datasheet and enquiry options from Precisometer.
TTL/Analog 1Hz-5KHz, 1Hz-10KHz, 1Hz-100KHz, and TTL on/off
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
OEM-DH-450: 450 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%, <3%, <5%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
OEM-DH-450: 450 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%, <3%, <5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
OEM-DH-450: 450 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%, <3%, <5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Spectrum analysis
OEM-DH-450: 450 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.
System integration
Integration and compatibility
Use these checks to connect OEM-DH-450 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Operating temperature (℃): 25+/-3 (OEM-DH-450) / 10-35 (OEM-DH-450-Water) · Cooled method: Water Cooled for OEM-DH-450-Water
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Technical FAQ
Integration questions for OEM-DH-450
What cooling does the OEM-DH-450 require?+
Operating temperature (℃): 25+/-3 (OEM-DH-450) / 10-35 (OEM-DH-450-Water) · Cooled method: Water Cooled for OEM-DH-450-Water. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare OEM-DH-450 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.