Back to Home

Power stability, linewidth, beam quality

MSL-T-770770 nm near-infrared single-frequency CW laser

770 nm

MSL-T-770 is a 770 nm CW laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� Single Longitudinal Mode Red Laser MSL-T- 770/ 1~300mW Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� �� ��. Key specifications: output / average power 1~300 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-T-770

2 specification rows

Wavelength770 nm
Output / average power1~300 mW
Beam / notesLinewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� Single Longitudinal Mode Red Laser MSL-T-770/ 1~300 mW Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� �� ��

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~40 mW
  • Output / average power: 1~2000 mW
  • Output / average power: 1~3000 mW
  • Operating mode: CW
  • Operating mode: Pulsed

Beam-quality tolerance context

Nearby series records state M²: <1.1, Beam divergence, full angle (mrad): <1.0, Beam divergence, full angle (mrad): <3.0, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for MSL-T-770; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

MSL-T-770: 770 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

MSL-T-770: 770 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

MSL-T-770: 770 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Measurement

MSL-T-770: Measurement benefits from a stable, focusable source. 770 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-T-770 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-T-770 (current)TUN-TiA-770-840TUN-TiN-770~840
Wavelength770 nm770 nm770 nm
Optical power / pulse energy1~300 mW1~2500 mW1~400 mW
Operating mode / pulse widthConfirm for this modelActively Q-switchedActively Q-switched
Beam qualityConfirm for this model<3.5<3.5