Back to Home

Power stability, linewidth, beam quality

MRL-FN-679679 nm red CW laser

679 nm

MRL-FN-679 is a 679 nm CW laser. Used for collimation, laser medical treatment, scientific experiments, optical instruments. Laser. Key specifications: output / average power 1~500 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MRL-FN-679

17 specification rows

Output / average power1~500 mW
Beam / notesLaser
Operating modeCW
Transverse modeTEM00
Beam diameter at the aperture (1/e2, mm)<1.5
Polarization ratio>100:1, Vertical (Horizontal optional)
Warm-up time (minutes)<5
Pointing stability over temperature (μrad/°C)<8
Operating temperature (°C)10-35
Modulation optionalDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Power supply (100-240VAC)PSU-H-FDA/ PSU-H-LED/PSU-SR
Expected lifetime (hours)>10000
Wavelength (nm)679±1
Output power (mW)1-500
Beam divergence, full angle (mrad)<1.5
Pointing Stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MRL-FN-679: Collimation benefits from a stable, focusable source. 679 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MRL-FN-679: 679 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiments

MRL-FN-679: 679 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instruments

MRL-FN-679: 679 nm emission determines compatible optics, coatings and detectors for Optical instruments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MRL-FN-679 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Beam diameter at the aperture (1/e2, mm): <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MRL-FN-679

What cooling does the MRL-FN-679 require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MRL-FN-679 deliver?

Transverse mode: TEM00 · Beam diameter at the aperture (1/e2, mm): <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MRL-FN-679 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMRL-FN-679 (current)MRL-FN-678MLL-III-680
Wavelength679 nm678 nm680 nm
Optical power / pulse energy1~500 mW1~100 mW1~1500 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00<3.0