Scientific experiments
MLL-U-946-SU: 946 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Power stability, linewidth, beam quality
MLL-U-946-SU is a 946 nm CW laser. Used for scientific experiments, optical sensing, measurement, instrumentation. Laser. Key specifications: output / average power 1~300 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.
Specifications
18 specification rows
| Output / average power | 1~300 mW |
|---|---|
| Beam / notes | Laser |
| Operating mode | CW |
| Transverse mode | TEM00 |
| Noise of amplitude (rms, 20Hz-20MHz) | <1% |
| M2 | <1.5 |
| Warm-up time (minutes) | <5 |
| Operating temperature (°C) | 10-35 |
| Power supply (100-240VAC) | PSU-H-FDA |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 946±1 |
| Spectral line width (nm) | <1.0, <0.1, (<0.006 optional@1-150) |
| M² | <1.5 |
| Beam diameter at the aperture (1/e2, mm) | ~1.5 |
| Beam divergence (mrad) | <1.5 |
| Polarization ratio | / |
| Pointing stability (μrad) (over 2 hours after warm-up and ±3°C) | <50 |
| Beam height from base plate (mm) | 27.4 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MLL-U-946-SU: 946 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MLL-U-946-SU: 946 nm emission determines compatible optics, coatings and detectors for Optical sensing. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MLL-U-946-SU: Measurement benefits from a stable, focusable source. 946 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
MLL-U-946-SU: 946 nm emission determines compatible optics, coatings and detectors for Instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect MLL-U-946-SU to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M2: <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MLL-U-946-SU with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
Compare the MLL-U-946-SU with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide