MLL-U-561-SM is a 561 nm CW laser. Used for scientific experiments, collimation, laser medical treatment, scientific experiment. Laser. Key specifications: output / average power 1~40 mW, operating mode CW, transverse mode TEM00 (single mode fiber output). View specifications, datasheet and enquiry options from Precisometer.
Typical uses for this laser type, with the selection logic tied to the model record.
Scientific experiments
MLL-U-561-SM: 561 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00 (single mode fiber output)) helps predict how the source will focus and propagate through the instrument.
Collimation
MLL-U-561-SM: Collimation benefits from a stable, focusable source. 561 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00 (single mode fiber output)) informs waist size and propagation.
Laser medical treatment
MLL-U-561-SM: 561 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00 (single mode fiber output)) helps predict how the source will focus and propagate through the instrument.
Scientific experiment
MLL-U-561-SM: 561 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00 (single mode fiber output)) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect MLL-U-561-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MLL-U-561-SM
How is the MLL-U-561-SM output delivered?+
Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
What cooling does the MLL-U-561-SM require?+
Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MLL-U-561-SM deliver?+
Transverse mode: TEM00 (single mode fiber output) · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.