Back to Home

Power stability, linewidth, beam quality

MLL-K-457457 nm blue CW laser

457 nm

MLL-K-457 is a 457 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Key specifications: operating mode CW, output power (w) 1-5, power stability (rms, 4 hours ± 3°c) <3%, <2%, (<1% optional). View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-K-457

22 specification rows

Beam / notesSeries: MLL-K-457
Operating modeCW
Output power (W)1-5
Power Stability (rms, 4 hours ± 3°C)<3%, <2%, (<1% optional)
Transverse modeTEM00
Spectral linewidth (nm)<0. 1
Noise of amplitude(rms, 20Hz-20MHz)<1%,(<0. 5% optional)
M2<1. 1
Beam divergence, full angle (mrad)~1.0
Pointing Stability Over Temperature (urad/°C)<20
Polarization ratio>50:1(>100:1 optional), Horizontal(Vertical optional)
Cooled methodWater cooled
Power supply (100-240VAC)PSU-W-LED
Expected lifetime (hours)>10000
Wavelength (nm)457±1
<1.1
Beam diameter at the aperture (1/e2, mm)<2.5
Warm-up time (minutes)<10
Pointing Stability(urad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)68
Operating temperature (°C)10-35
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MLL-K-457: 457 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MLL-K-457: 457 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MLL-K-457: 457 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

MLL-K-457: 457 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect MLL-K-457 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water cooled · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1. 1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-K-457

What cooling does the MLL-K-457 require?

Cooled method: Water cooled · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-K-457 deliver?

Transverse mode: TEM00 · M2: <1. 1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-K-457 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-K-457 (current)MSL-R-457Low Noise
Wavelength457 nm457 nm457 nm
Optical power / pulse energy1-5Water cooled350-1000 mW
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityTEM00TEM00Confirm for this model