MLL-III-785-Lock is a 785 nm CW laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. Low Noise Infrared Laser. Key specifications: output / average power 1~600 mW, operating mode CW, spectral line width (nm) <0.2, <0.1, <0. 06. View specifications, datasheet and enquiry options from Precisometer.
DC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
DNA sequencing
MLL-III-785-Lock: 785 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
MLL-III-785-Lock: 785 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
MLL-III-785-Lock: 785 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Measurement
MLL-III-785-Lock: Measurement benefits from a stable, focusable source. 785 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Multimode) informs waist size and propagation.
System integration
Integration and compatibility
Use these checks to connect MLL-III-785-Lock to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Conduction · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Multimode · Beam divergence, full angle (mrad): <3.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MLL-III-785-Lock
What cooling does the MLL-III-785-Lock require?+
Cooled method: Conduction · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MLL-III-785-Lock deliver?+
Transverse mode: Multimode · Beam divergence, full angle (mrad): <3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MLL-III-785-Lock with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.