Back to Home

Power stability, linewidth, beam quality

MLL-III-1410-SM1410 nm infrared CW laser

1410 nm

MLL-III-1410-SM is a 1410 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Laser. Key specifications: output / average power 1~15 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-III-1410-SM

16 specification rows

Wavelength1410 nm
Output / average power1~15 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
Noise of amplitude (rms, 20Hz-20MHz)<1%, <0.5%
Fiber typeSM fiber, PM fiber optional
Fiber Core diameter4-9μm, 0.12NA
Fiber connectorFC/PC, FC/APC optional
Fiber jacketMetal, PVC optional
Transverse modeTEM00
M2 after fiber~1.1
Warm-up time (minutes)<5
Cooled methodConduction
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MLL-III-1410-SM: 1410 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MLL-III-1410-SM: 1410 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MLL-III-1410-SM: 1410 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MLL-III-1410-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: SM fiber, PM fiber optional · Fiber Core diameter: 4-9μm, 0.12NA
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Conduction · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2 after fiber: ~1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-III-1410-SM

How is the MLL-III-1410-SM output delivered?

Fiber type: SM fiber, PM fiber optional · Fiber Core diameter: 4-9μm, 0.12NA. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MLL-III-1410-SM require?

Cooled method: Conduction · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-III-1410-SM deliver?

Transverse mode: TEM00 · M2 after fiber: ~1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-III-1410-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-III-1410-SM (current)MIL-H-1413MLL-III-1420
Wavelength1410 nm1413 nm1420 nm
Optical power / pulse energy1~15 mW1~300 mW1~500 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00Multimode