Back to Home

Power stability, linewidth, beam quality

MLL-FN-639639 nm red CW laser

639 nm

MLL-FN-639 is a 639 nm CW laser. Used for collimation, laser medical treatment, scientific experiments, optical instrument. L inewidth<0.003 nm optional. Key specifications: output / average power 1~1500 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-FN-639

13 specification rows

Wavelength639 nm
Output / average power1~1500 mW
Beam / notesL inewidth<0.003 nm optional
Operating modeCW
Transverse modeTEM00
Polarization ratio>100:1, Horizontal (Vertical optional)
Warm-up time (minutes)<5
Pointing stability over temperature (urad/°C)<8
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA
Operating voltage (VDC)PSU-SR-OEM (12V/25A)
Expected lifetime (hours)>10000
Pointing stability (urad) (over 2 hours after warm-up and±3°C)<50
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MLL-FN-639: Collimation benefits from a stable, focusable source. 639 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MLL-FN-639: 639 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiments

MLL-FN-639: 639 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instrument

MLL-FN-639: 639 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MLL-FN-639 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Polarization ratio: >100:1, Horizontal (Vertical optional)
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-FN-639

What cooling does the MLL-FN-639 require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-FN-639 deliver?

Transverse mode: TEM00 · Polarization ratio: >100:1, Horizontal (Vertical optional). Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-FN-639 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-FN-639 (current)MSL-FN-639MSL-R-639
Wavelength639 nm639 nm639 nm
Optical power / pulse energy1~1500 mW1~650 mW650~3000 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00