Back to Home

Power stability, linewidth, beam quality

MLL-395(FC)395 nm UV CW laser

395 nm

MLL-395(FC) is a 395 nm CW laser. Key specifications: output / average power 1~80 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-395(FC)

1 specification rows

Wavelength395 nm
Output / average power1~80 mW

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~100 mW
  • Output / average power: 1~500 mW
  • Output / average power: 1~80 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state M²: <1.5, Beam divergence, full angle (mrad): <1.0, Beam divergence, full angle (mrad): <0.5×2.0, and Beam divergence, full angle (mrad): <2.0×0.5. These are series context, not guaranteed values for MLL-395(FC); confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

MLL-395(FC): 395 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

MLL-395(FC): Laboratory measurement benefits from a stable, focusable source. 395 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-395(FC) with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-395(FC) (current)MLL-III-397LMLL-III-397
Wavelength395 nm397 nm397 nm
Optical power / pulse energy1~80 mW1~100 mW1~100 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this model<1.0Multimode