Back to Home

Power stability, linewidth, beam quality

MIL-W-36003600 nm infrared CW laser

3600 nm

MIL-W-3600 is a 3600 nm CW laser. Used for spectroscopy, remote sensing, medical. CW Mid-Infrared Laser. Key specifications: operating mode CW, output / average power 250~1000 mW, power stability (rms, 4 hours±3℃) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MIL-W-3600

9 specification rows

Wavelength3600 nm
Operating modeCW
Output / average power250~1000 mW
Beam / notesCW Mid-Infrared Laser
Power stability (rms, 4 hours±3℃)<5%, <3%
Beam divergence, full angle (mrad)<11
Cooled methodAir Cooled
Operating temperature (℃)15-35
Power supply (100-240VAC)RAD1PS
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Spectroscopy

MIL-W-3600: 3600 nm emission sets the excitation and detector-band choice for Spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<11) also controls focusing and collection geometry.

Remote sensing

MIL-W-3600: 3600 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<11) helps predict how the source will focus and propagate through the instrument.

Medical

MIL-W-3600: 3600 nm emission determines compatible optics, coatings and detectors for Medical. The catalogued beam parameter (<11) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MIL-W-3600 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <11
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MIL-W-3600

What cooling does the MIL-W-3600 require?

Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MIL-W-3600 deliver?

Beam divergence, full angle (mrad): <11. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MIL-W-3600 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMIL-W-3600 (current)MDL-XN-3600MIL-V-3600
Wavelength3600 nm3600 nm3600 nm
Optical power / pulse energy250~1000 mW1~200 mW1~400 mW
Operating mode / pulse widthCWCWCW
Beam quality<11Near TEM00<5