MIL-V-3390: 3390 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.
Power stability, linewidth, beam quality
MIL-V-3390 is a 3390 nm CW laser. Used for remote sensing, communication, spectrum analysis. CW Mid-Infrared Laser. Key specifications: operating mode CW, output / average power 1~250 mW, power stability (rms, 4 hours±3℃) <3%, <2%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
13 specification rows
| Operating mode | CW |
|---|---|
| Output / average power | 1~250 mW |
| Beam / notes | CW Mid-Infrared Laser |
| Power stability (rms, 4 hours±3℃) | <3%, <2% |
| Beam divergence, full angle (mrad) | <5 |
| Warm-up time (minutes) | <10 |
| Cooled method | Air Cooled |
| Operating temperature (℃) | 15-35 |
| Power supply (100-240VAC) | RAD1PS |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 3390±5 |
| Beam diameter at the aperture (1/e2,mm) | <6 |
| Beam height from base plate (mm) | 82 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MIL-V-3390: 3390 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.
MIL-V-3390: 3390 nm emission must sit inside the fiber-component passband used for Communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.
MIL-V-3390: 3390 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<5) also controls focusing and collection geometry.
System integration
Use these checks to connect MIL-V-3390 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <6. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MIL-V-3390 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MIL-V-3390 (current) | MIL-W-3390 | TUN-W-2600~4410 |
|---|---|---|---|
| Wavelength | 3390 nm | 3390 nm | 3390 nm |
| Optical power / pulse energy | 1~250 mW | 250~1000 mW | 250~1000 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | <5 | <11 | <11 |
Compare the MIL-V-3390 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide