Back to Home

Power stability, linewidth, beam quality

MDL-XD-462462 nm blue CW laser

462 nm

MDL-XD-462 is a 462 nm CW laser. Used for laser projection, stage lighting, biomedical applications, metrology. Laser. Key specifications: output / average power 8~16 W, operating mode CW, power stability (rms, over 4 hours) <1%, <2%, <3%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-XD-462

12 specification rows

Wavelength462 nm
Output / average power8~16 W
Beam / notesLaser
Operating modeCW
Power stability (rms, over 4 hours)<1%, <2%, <3%
Polarization directionHorizontal+Vertical
Beam divergence, full angle (mrad)<2.4×2.0
Warm-up time (minutes)<5
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-N-LED/ PSU-N-FDA
Expected lifetime (hours)10000
TTL / Analog modulationTTL or Analog with 1Hz-1kHz 1kHz-10kHz, 10kHz-30kHz optional
Warranty1 year

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Laser projection

MDL-XD-462: 462 nm emission determines compatible optics, coatings and detectors for Laser projection. The catalogued beam parameter (<2.4×2.0) helps predict how the source will focus and propagate through the instrument.

Stage lighting

MDL-XD-462: 462 nm emission determines compatible optics, coatings and detectors for Stage lighting. The catalogued beam parameter (<2.4×2.0) helps predict how the source will focus and propagate through the instrument.

Biomedical applications

MDL-XD-462: 462 nm emission determines compatible optics, coatings and detectors for Biomedical applications. The catalogued beam parameter (<2.4×2.0) helps predict how the source will focus and propagate through the instrument.

Metrology

MDL-XD-462: 462 nm emission determines compatible optics, coatings and detectors for Metrology. The catalogued beam parameter (<2.4×2.0) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MDL-XD-462 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Polarization direction: Horizontal+Vertical · Beam divergence, full angle (mrad): <2.4×2.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-XD-462

What cooling does the MDL-XD-462 require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-XD-462 deliver?

Polarization direction: Horizontal+Vertical · Beam divergence, full angle (mrad): <2.4×2.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-XD-462 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-XD-462 (current)MLL-III-462MLL-F-462
Wavelength462 nm462 nm462 nm
Optical power / pulse energy8~16 W1~800 mW800~1500 mW
Operating mode / pulse widthCWCWCW
Beam quality<2.4×2.0<2.1×1.6 / <2.5×0.2Multimode