Power stability, linewidth, beam quality

MDL-III-1050-SLD-SM1050 nm near-infrared CW laser

1050 nm

MDL-III-1050-SLD-SM is a 1050 nm CW laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. SM Fiber output. Key specifications: output / average power 1~17 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-III-1050-SLD-SM

2 specification rows

Wavelength1050 nm
Output / average power1~17 mW
Beam / notesSM Fiber output

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~17 mW
  • Output / average power: 1~500 mW
  • Output / average power: 1~1000 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours , ±3°C): <3%, <2%, <1%

Beam-quality tolerance context

Nearby series records state M²: <1.2, M²: <1.5, M²: <2.0, and Beam divergence (mrad): <1.5. These are series context, not guaranteed values for MDL-III-1050-SLD-SM; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser source and internal thermal control
  2. Step 2Configured fiber launch or integrated pigtail
  3. Step 3Mode- and connector-matched patch lead
  4. Step 4Collimator, isolator or experiment input

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

MDL-III-1050-SLD-SM: 1050 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

MDL-III-1050-SLD-SM: 1050 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

MDL-III-1050-SLD-SM: 1050 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Measurement

MDL-III-1050-SLD-SM: Measurement benefits from a stable, focusable source. 1050 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-III-1050-SLD-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-III-1050-SLD-SM (current)MDL-III-1050-SLDMSL-U-1047-SU
Wavelength1050 nm1050 nm1047 nm
Optical power / pulse energy1~17 mW1~17 mW1~500 mW
Operating mode / pulse widthConfirm for this modelConfirm for this modelCW
Beam qualityConfirm for this modelConfirm for this modelTEM00