Back to Home

Power stability, linewidth, beam quality

MDL-H-800800 nm near-infrared CW laser

800 nm

MDL-H-800 is a 800 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. High Stability Infrared Laser. Key specifications: output / average power 1~2500 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-H-800

16 specification rows

Output / average power1~2500 mW
Beam / notesHigh Stability Infrared Laser
Operating modeCW
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
Transverse modeMultimode
Beam divergence, full angle (mrad)<3.0
Warm-up time (minutes)<5
Cooled methodAir cooled
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA/PSU-H-LED
Expected lifetime (hours)>10000
Central wavelength (nm)800±5
Output power (mW)1-2500
Beam diameter at the aperture (mm)~5×8
Beam height from base plate (mm)29
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MDL-H-800: 800 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MDL-H-800: 800 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-H-800: 800 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MDL-H-800 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Multimode · Beam divergence, full angle (mrad): <3.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-H-800

What cooling does the MDL-H-800 require?

Cooled method: Air cooled · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-H-800 deliver?

Transverse mode: Multimode · Beam divergence, full angle (mrad): <3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-H-800 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-H-800 (current)MDL-800(FC)FC-800
Wavelength800 nm800 nm800 nm
Optical power / pulse energy1~2500 mW1 mW~2 W1~10 W
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityMultimodeMultimodeConfirm for this model