Back to Home

Power stability, linewidth, beam quality

MBL-434(FC)434 nm violet CW laser

434 nm

MBL-434(FC) is a 434 nm CW laser. Key specifications: output / average power 1~85 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MBL-434(FC)

1 specification rows

Wavelength434 nm
Output / average power1~85 mW

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~300 mW
  • Output / average power: 1~500 mW
  • Output / average power: 500~4000 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours±3℃): <3%, <2%, (<1% optional@Water Cooled)

Beam-quality tolerance context

Nearby series records state M²: ~3.0, Beam divergence (mrad): <3.0, Beam divergence, full angle (mrad): <2.1×1.6, and Beam divergence, full angle (mrad): <2.5×0.2. These are series context, not guaranteed values for MBL-434(FC); confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

MBL-434(FC): 434 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

MBL-434(FC): Laboratory measurement benefits from a stable, focusable source. 434 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MBL-434(FC) with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMBL-434(FC) (current)MBL-U-433-SFMLL-III-435
Wavelength434 nm433 nm435 nm
Optical power / pulse energy1~85 mW1~300 mW1~500 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelTEM00<2.1×1.6