420 nm

H-420 is a 420 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Laser. Key specifications: output / average power 500~1300 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

H-420

2 specification rows

Wavelength420 nm
Output / average power500~1300 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 4 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~100 mW
  • Output / average power: 1~500 mW
  • Output / average power: 500~1300 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state Beam divergence, full angle (mrad): <1.0 and Beam divergence, full angle (mrad): <2.5×0.2. These are series context, not guaranteed values for H-420; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

H-420: 420 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

H-420: 420 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

H-420: 420 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Spectrum analysis

H-420: 420 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare H-420 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterH-420 (current)MLL-III-420LMLL-III-420
Wavelength420 nm420 nm420 nm
Optical power / pulse energy500~1300 mW1~100 mW1~500 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelNear TEM00<2.5×0.2