Back to Home

Power stability, linewidth, beam quality

FC-OEM-830-A830 nm near-infrared CW laser

830 nm

FC-OEM-830-A is a 830 nm CW laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. Integrated optoelectronic. Key specifications: output / average power 1~270 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-OEM-830-A

2 specification rows

Wavelength830 nm
Output / average power1~270 mW
Beam / notesIntegrated optoelectronic

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 24 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~1500 mW
  • Output / average power: 1~5 W
  • Output / average power: 1~50 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state M²: <1.5, M²: <1.1, Beam divergence, full angle (mrad): <1.0, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for FC-OEM-830-A; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

FC-OEM-830-A: 830 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

FC-OEM-830-A: 830 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

FC-OEM-830-A: 830 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Measurement

FC-OEM-830-A: Measurement benefits from a stable, focusable source. 830 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-OEM-830-A with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-OEM-830-A (current)MDL-830(FC)FC-830
Wavelength830 nm830 nm830 nm
Optical power / pulse energy1~270 mW1~1500 mW1~5 W
Operating mode / pulse widthConfirm for this modelCWConfirm for this model
Beam qualityConfirm for this model<1.0Confirm for this model