Back to Home

Power stability, linewidth, beam quality

FC-622622 nm red CW laser

622 nm

FC-622 is a 622 nm CW laser. Key specifications: output / average power 1~45 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-622

1 specification rows

Wavelength622 nm
Output / average power1~45 mW

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 4 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~50 mW
  • Output / average power: 50~100 mW
  • Output / average power: 1~45 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours±3℃): <3%, <2%, <1%

Beam-quality tolerance context

Nearby series records state M²: <1.2, Beam divergence, full angle (mrad): <1.5, Beam divergence, full angle (mrad): <3.0, and Pointing Stability(μrad) (over 2 hours after warm-up and ±3°C): <50. These are series context, not guaranteed values for FC-622; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

FC-622: 622 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

FC-622: Laboratory measurement benefits from a stable, focusable source. 622 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-622 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-622 (current)MRL-FN-622MRL-DP-622-B
Wavelength622 nm622 nm622 nm
Optical power / pulse energy1~45 mW1~50 mW50~100 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelTEM00Near TEM00 (TEM00 optional)