Optical instrumentation
FC-1870: 1870 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Power stability, linewidth, beam quality
FC-1870 is a 1870 nm CW laser. Key specifications: output / average power 1~1000 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
16 specification rows
| Output / average power | 1~1000 mW |
|---|---|
| Operating mode | CW |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1%, <0.5% |
| Fiber core | 400µm, 0.22 NA |
| Fiber connector | SMA905, FC/PC optional |
| Fiber jacket | Metal, PVC optional |
| Warm-up time (minutes) | <5 |
| Cooled method | Air cooled |
| Operating temperature (℃) | 10-35 |
| Operating voltage (VAC) | 100-240 |
| Expected lifetime (hours) | >10000 |
| Central wavelength (nm) | 1870±20 |
| Output power after fiber (mW) | 1-1000 |
| Fiber core diameter | 400µm, 0.22 NA |
| Fiber length | 1m |
| Modulation option | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
FC-1870: 1870 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
FC-1870: Laboratory measurement benefits from a stable, focusable source. 1870 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
System integration
Use these checks to connect FC-1870 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Fiber core: 400µm, 0.22 NA · Fiber connector: SMA905, FC/PC optional. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare FC-1870 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | FC-1870 (current) | MDL-H-1870 | MDL-1870(FC) |
|---|---|---|---|
| Wavelength | 1870 nm | 1870 nm | 1870 nm |
| Optical power / pulse energy | 1~1000 mW | 1~800 mW | 1~650 mW |
| Operating mode / pulse width | CW | CW | Confirm for this model |
| Beam quality | Confirm for this model | Multimode | Confirm for this model |
Compare the FC-1870 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide