Back to Home
Precisometer · Official representative

Neutron detection

Neutron sCMOS detector

LiF:ZnS:Ag scintillator imaging coupled to a low-noise cooled detector for neutron radiography and tomography.

Neutron sCMOS detector

Representative manufacturer photograph; housing and connectors depend on the selected configuration. Select the photograph to enlarge.

Scintillator
LiF:ZnS:Ag
Input area
43 × 43 cm
Effective pitch
105 µm
Frame rate
5 fps
Cooling
Operating at −20°C
Interface
Gigabit Ethernet

From photon to signal

Response for your configuration.

Full specifications

The manufacturer does not publish a complete QE curve for this configuration. The available detector and converter specifications are listed below; efficiency must be specified for the neutron spectrum and selected scintillator thickness.

The details behind the selection

Full technical specifications.

Compare sensor configurations, coating options, operating limits and integration details directly below. Check the operating mode and temperature alongside each performance value.

01

Neutron detector specifications

9 parameters
Neutron detector specifications
ParameterPublished specification
ScintillatorLiF:ZnS:Ag
Pixel Size (μm)105
Input Size (cm)43 x 43
Frame Rate (fps)5
Dynamic Range>20,000:1
Read Out Noise4
Sensor Temperature (ºC)Operating at -20
Exposure Time (mins)up to 1
Camera InterfaceGigabit Ethernet
02

Neutron scintillator properties

9 parameters
Neutron scintillator properties
ParameterPublished specification
Screen TypeND
Phosphor TypeParticulate blend
Emission ColourBlue
Peak Emission (nm)450
Decay to 10% (μs)3.5
Peak Emission<3e
After GlowLow level
X-ray AbsorptionVery low
UV AbsorptionBroad band

Key Features

  • Real time acquisition of 16 bit digitised image
  • Single neutron equivalent read out noise
  • Very high dynamic range up to 20,000:1
  • Genicam compliance
  • Multiplexed acquisition from tiled arrays

Build your enquiry

Start with the detector.

Choose a published configuration, add the integration topics you want to discuss, and keep the exact model in your enquiry.

Neutron sCMOS detector configuration and enquiry
Your starting configuration

Neutron sCMOS 43 × 43 cm

Sensor / coating
LiF:ZnS:Ag scintillator + sCMOS
Pixel pitch
105 µm effective
Active input
43 × 43 cm
Acquisition
5 fps
Cooling
−20°C
Read noise
4 e− (published)
Interface
GigE
Optical / mechanical interface
Scintillator-screen imaging geometry
Spectral response
Neutron detection; LiF:ZnS:Ag converter

Selected options are requirements for discussion. Compatibility and final performance are confirmed for your configuration.

Review enquiry

Discuss selection, integration and a quotation with Precisometer.

The manufacturer also references intensified neutron solutions. Discuss intensifier and scintillator requirements for time-resolved detection.

Technical overview

Designed around the measurement.

LiF:ZnS:Ag scintillator imaging coupled to a low-noise cooled detector for neutron radiography and tomography.

Neutron radiographyNeutron tomographyMaterials characterisation
Neutron sCMOS detector technical overview
ScintillatorLiF:ZnS:Ag
Input area43 × 43 cm
Effective pitch105 µm
Frame rate5 fps
CoolingOperating at −20°C
InterfaceGigabit Ethernet

Explore the wider range

Other routes to your measurement.

All Photonic Science products
Product selection

What do you need to measure?

Start with your signal, or search directly for a camera, sensor option or application.

1 product ranges · 0 camera configurations

OEM & custom imaging

Representative equipment; the complete configuration depends on your application.

Photonic Science / Integration & accessories

OEM & custom imaging

Custom camera and detector integration from sensor selection and cooling through mechanics, interfaces and software.

Technologies
CCD, sCMOS, InGaAs and intensified imaging
Engineering
Form factor, cooling, optics, interfaces and software
Explore the solution