Back to Home
Precisometer · Official representative

UV, visible & NIR

ELSE-s

Deep-cooled, full-frame CCD spectroscopy for weak optical signals across UV, visible and near infrared.

ELSE-s

Representative manufacturer photograph; housing and connectors depend on the selected configuration. Select the photograph to enlarge.

Detector
Full-frame scientific CCD
Digitization
18-bit
Data interfaces
Gigabit Ethernet and USB 3.0
Environment
Laboratory optical imaging
Sensor choices
Front-illuminated, back-illuminated and deep-depletion options; model dependent

From photon to signal

QE & spectral response.

Full specifications

Select the sensor coating for the actual wavelength or photon energy. The plots below preserve the manufacturer’s axes, legends and response conditions.

Platform QE, up to
98%

Select a figure to inspect the original axes, legend and curves.

Original manufacturer curves for the sensor and coating codes shown in the legend. Match the selected code to the performance matrix; the curves are reference response data, not a guaranteed value at every wavelength.

Quantum efficiency & spectral response

Quantum efficiency & spectral response — enlarged manufacturer figure

Original manufacturer curves for the sensor and coating codes shown in the legend. Match the selected code to the performance matrix; the curves are reference response data, not a guaranteed value at every wavelength.

The details behind the selection

Full technical specifications.

Compare sensor configurations, coating options, operating limits and integration details directly below. Check the operating mode and temperature alongside each performance value.

01

Sensor configurations & performance

15 parameters
Sensor configurations & performance
ELSEs SeriesELSEs 1k128ELSEs 1k256ELSEs 2k256ELSEs 2k512
Enhanced UV sensitivity——OE UV BI UV2 BI UV3—FI UV BI UV2 BI UV3
Enhanced VIS sensitivityFI BI MIDFI BI MIDFIFI BI MID
Enhanced NIR sensitivityDD NIRFI DD DD NIR DD MU2DD NIR—
Usable pixels (columns x rows)1024 x 1271024 x 2552048 x 2642048 x 515
Active image area26.6 mm x 3.3 mm26.6 mm x 6.7 mm30.7 mm x 3.9 mm27.6 mm x 6.9 mm
Pixel size26 µm x 26 µm15 µm x 15 µm13.5 µm x 13.5 µm
Full well capacity300 ke- (OE UV) / 500 ke- / 700 ke- (DD)75 ke-100 ke-
Register well capacity1 000 ke- / 1 400 ke- (DD)650 ke-400 ke-
Dark Current @ -100°C0.0004 e-/pixels/s 0.005 e-/pixels/s (DD)0.0006 e-/pixels/s-0.00025 e-/pixels/s
Typical read noise (e-) @ 50 kHz @ 1 MHz @ 3 MHz5.5 12.5 26.0FI 4.2 12.0 25.0BI 6.0 13.1 26.0DD 5.4 12.3 25.03.7 7.0 12.13.5 6.8 10.7
Standard Mode gain0.4 counts/e-0.4 counts/e-1.5 counts/e-1 counts/e-
High Capacity Mode gain---0.34 counts/e-
CCD sensor typeFront-illuminated (FI), Back-illuminated (BI), Deep depletion fringe suppression (DD), Open-electrode (OE)
Antireflective coatingUV (UV2, UV3), midband (MID), multiband (MU2), near-infrared (NIR)
Blemish specificationsGrade 0 or Grade 1 (standard) as specified by sensor manufacturer.

Compare performance at the stated readout frequency or acquisition mode, sensor temperature and coating. A dash does not mean zero.

02

Common camera specifications

16 parameters
Common camera specifications
ParameterPublished specification
Pixel readout frequency50 kHz, 250 kHz, 1 MHz, 3 MHz (5 MHz for visualisation mode)
AD converter resolution18-bit
LinearityBetter than 99%
Window materialMgF2 or UVFS for UV sensitive models, otherwise BK7
Distance flange - focal plane10.0 mm
CCD sensor cooling-100°C to 20°C, forced air or liquid cooling
Temperature monitoringTwo thermistors at CCD sensor and thermoelectric cooler (hot side)
Data linkGigabit Ethernet, USB 3.0
Softwaregreateyes Vision software for Windows 11
SDK and driversDLL for Windows; LabVIEW, EPICS, Linux, Python, Tango driver (optional)
TTL interface signalsExposure out, shutter out, 2 external trigger in
Operating conditionsTemperature: 0°C to 35°C ambient, relative humidity <80% (non-condensing)
Power supply80-264 VAC (115/230 typical), 47-63 Hz (50/60 typical), max. 1.1 A (230 VAC), 1.9 A (115 VAC)
CertificationCE
Dimensions (W x H x L)8.3 cm x 10.0 cm x 13.1 cm (3.27" x 3.94" x 5.16")
Weight2.2 kg
03

ELSEs 1k128 — dimensions & configuration

7 parameters
ELSEs 1k128 — dimensions & configuration
ParameterPublished specification
Image area26.6 mm × 3.3 mm
Pixel format1024 × 127 pixels
Pixel size26 µm × 26 µm
CCD sensor coolingMin. -100°C to 20°C, forced air or liquid cooling
Distance flange - focal plane10.0 mm
Dimensions (W x H x L)8.3 cm × 10.0 cm × 13.1 cm (3.27" × 3.94" × 5.16")
Weight2.2 kg
04

ELSEs 1k256 — dimensions & configuration

7 parameters
ELSEs 1k256 — dimensions & configuration
ParameterPublished specification
Image area26.6 mm × 6.7 mm
Pixel format1024 × 255 pixels
Pixel size26 µm × 26 µm
CCD sensor coolingMin. -100°C to 20°C, forced air or liquid cooling
Distance flange - focal plane10.0 mm
Dimensions (W x H x L)8.3 cm × 10.0 cm × 13.1 cm (3.27" × 3.94" × 5.16")
Weight2.2 kg
05

ELSEs 2k256 — dimensions & configuration

7 parameters
ELSEs 2k256 — dimensions & configuration
ParameterPublished specification
Image area30.7 mm × 3.9 mm
Pixel format2048 × 264 pixels
Pixel size15 µm × 15 µm
CCD sensor coolingMin. -100°C to 20°C, forced air or liquid cooling
Distance flange - focal plane10.0 mm
Dimensions (W x H x L)8.3 cm × 10.0 cm × 13.1 cm (3.27ʺ × 3.94ʺ × 5.16ʺ)
Weight2.2 kg
06

ELSEs 2k512 — dimensions & configuration

7 parameters
ELSEs 2k512 — dimensions & configuration
ParameterPublished specification
Image area27.6 mm × 6.9 mm
Pixel format2048 × 512 pixels
Pixel size13.5 µm × 13.5 µm
CCD sensor coolingMin. -100°C to 20°C, forced air or liquid cooling
Distance flange - focal plane10.0 mm
Dimensions (W x H x L)8.3 cm × 10.0 cm × 13.1 cm (3.27" × 3.94" × 5.16")
Weight2.2 kg
07

Included software & equipment

7 parameters
Included software & equipment
Order codeIncluded equipment
GE-VI01greateyes Vision software suite for Windows
GE-SDK01SDK for Windows (C/C++ based)
GE-USB3m33m USB 3.0 cable type A to type C
GE-GigE10m10m Ethernet cable
GE-StoB2m2m SMB to BNC connection cable x2
GE-POW01Camera power supply with cabling
GE-ManCamCamera instruction manual
08

Compatible accessories, cooling & drivers

12 parameters
Compatible accessories, cooling & drivers
Order CodeDescription
Accessories for Imaging Purposes
GE-FM02F-mount lens adaptor (integrated filter holder optional)
EL-SR4545mm shutter, including shutter driver module
Accessories for Enhanced Cooling Performance
GE-CR01Compact liquid cooling, circulating the coolant at room temperature for deep camera cooling
GE-CR02Recirculating water chiller, PID control with temp. from -5°C to 30°C for ultra-deep camera cooling
Software Development Kit (SDK) and Drivers
GE-LX01SDK for Linux (C/C++ based)
GE-PYT01Python driver
GE-LAB01LabVIEW driver
GE-EPEPICS driver
GE-TANTango driver

Detector platform capabilities

  • Ultra deep TE cooling down to -100°C — lowest dark current for better detection limit
  • Hermetic vacuum seal — low camera maintenance and sensor protection
  • GigE & USB 3.0 data interface — local or remote network operation – your choice!
  • Multiple sensor options — UV, VIS, or NIR coatings for different sensor formats
  • High QE up to 98% — very sensitive sensors for low light applications
  • User selectable gain — balance your detector for best SNR and dynamic range
  • Fast readout speeds up to 5 MHz — fast frame rates paired with low-noise electronics
  • Flexible software options — camera software and SDKs available

Plan the integration

Mechanical drawings.

Enlarge the mounting, connector and camera-outline drawings. Dimensions and model dependencies are retained.

Manufacturer drawing in the original units. Camera body, sensor location, ports and flange depend on the selected format and housing; use the model dimensions table to confirm the configuration.

Mechanical drawing & connections

Mechanical drawing & connections — enlarged manufacturer figure

Manufacturer drawing in the original units. Camera body, sensor location, ports and flange depend on the selected format and housing; use the model dimensions table to confirm the configuration.

Build your enquiry

Start with the detector.

Choose a published configuration, add the integration topics you want to discuss, and keep the exact model in your enquiry.

ELSE-s configuration and enquiry
Your starting configuration

ELSE-s 1k256 OE UV

Sensor / coating
Scientific CCD · OE UV
Pixels
1024 × 255
Pixel pitch
26 µm
Active input
26.6 × 6.7 mm
Cooling
−100°C to +20°C
Read noise
4.2 e− @ 50 kHz
Interface
GigE / USB 3.0
Optical / mechanical interface
Spectrograph interface; adaptor matched to instrument
Spectral response
UV / visible / NIR; response depends on sensor coating
Shutter / sensor readout
CCD
Digitization
18-bit
Readout
50 kHz to 5 MHz; mode dependent

Selected options are requirements for discussion. Compatibility and final performance are confirmed for your configuration.

Review enquiry

Discuss selection, integration and a quotation with Precisometer.

ELSE-s configurations
ConfigurationPixelsPitch / inputCooling / acquisitionRead noise
1024 × 12726 µm
26.6 × 3.3 mm
−100°C to +20°C
5.5 e− @ 50 kHz
1024 × 12726 µm
26.6 × 3.3 mm
−100°C to +20°C
5.5 e− @ 50 kHz
1024 × 12726 µm
26.6 × 3.3 mm
−100°C to +20°C
5.5 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
4.2 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
6.0 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
6.0 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
4.2 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
6.0 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
5.4 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
5.4 e− @ 50 kHz
1024 × 25526 µm
26.6 × 6.7 mm
−100°C to +20°C
5.4 e− @ 50 kHz
2048 × 26415 µm
30.7 × 3.9 mm
−100°C to +20°C
3.7 e− @ 50 kHz
2048 × 26415 µm
30.7 × 3.9 mm
−100°C to +20°C
3.7 e− @ 50 kHz
2048 × 51513.5 µm
27.6 × 6.9 mm
−100°C to +20°C
3.5 e− @ 50 kHz
2048 × 51513.5 µm
27.6 × 6.9 mm
−100°C to +20°C
3.5 e− @ 50 kHz
2048 × 51513.5 µm
27.6 × 6.9 mm
−100°C to +20°C
3.5 e− @ 50 kHz
2048 × 51513.5 µm
27.6 × 6.9 mm
−100°C to +20°C
3.5 e− @ 50 kHz
2048 × 51513.5 µm
27.6 × 6.9 mm
−100°C to +20°C
3.5 e− @ 50 kHz

Cooling limits depend on the selected sensor, ambient conditions and cooling arrangement. Read noise values are typical at the specified pixel-readout frequency; they are not frame rates.

Technical overview

Designed around the measurement.

Deep-cooled, full-frame CCD spectroscopy for weak optical signals across UV, visible and near infrared.

Raman / LIBS spectroscopyFluorescence & luminescenceAstronomy
ELSE-s technical overview
DetectorFull-frame scientific CCD
Digitization18-bit
Data interfacesGigabit Ethernet and USB 3.0
EnvironmentLaboratory optical imaging
Sensor choicesFront-illuminated, back-illuminated and deep-depletion options; model dependent

Explore the wider range

Other routes to your measurement.

All Greateyes products
Product selection

What do you need to measure?

Start with your signal, or search directly for a camera, sensor option or application.

6 product ranges · 34 camera configurations

ELSE-i
Greateyes / UV, visible & NIR

ELSE-i

Deep-cooled, full-frame CCD imaging for weak optical signals across UV, visible and near infrared.

Detector
Full-frame scientific CCD
Digitization
18-bit
18 configurations · specifications
ALEX-s
Greateyes / Direct VUV, EUV & X-ray

ALEX-s

Direct-detection CCD spectroscopy for VUV, EUV and X-ray experiments, with a vacuum flange interface to the experiment.

Detector
Full-frame scientific CCD
Digitization
18-bit
7 configurations · specifications
LOTTE-s
Greateyes / In-vacuum CCD

LOTTE-s

Direct-detection CCD spectroscopy for VUV, EUV and X-ray experiments, with the complete detector operating inside the vacuum chamber.

Detector
Full-frame scientific CCD
Digitization
18-bit
7 configurations · specifications
CHARLIE
Greateyes / Direct VUV, EUV & X-ray

CHARLIE

Back-illuminated sCMOS direct detection for experiments that need higher acquisition rates alongside deep cooling.

Sensor
GSENSE400BSI; 2048 × 2048 pixels
Pixel pitch
11 µm
1 configurations · specifications
Custom scientific cameras

Representative equipment; the complete configuration depends on your application.

Greateyes / Custom & space

Custom scientific cameras

Adapt sensor position, cooling, vacuum mechanics or readout to the geometry of your experiment.

Customisation
Tilted, extruded or detached sensors
Mechanics
Housing, vacuum flange and sensor position
Explore the solution
URSA space imaging

Representative equipment; the complete configuration depends on your application.

Greateyes / Custom & space

URSA space imaging

A modular scientific imaging platform for mission-specific space instruments, developed with XCAM Scientific.

Architecture
Modular, configurable imaging and readout platform
Sensors
Scientific CMOS; multi-sensor integration supported
1 configurations · specifications